to answer your query, 46212.95mm2 is the total leg area provided on drawing (35Y29@100 c/c) over a distance of 3500mm from the surface of block, which is provided to meet both the end block/anchorage design and knee joint detailing requirements. Item3 in previous email is only a check to see whether the provided reinforcement is sufficient or not to disperse the concentrated prestress forces.